CONTROL PANEL FEATURES
- 8 Zones: 7 E.O.L. Supervised
Programmable Zones: 6 Burglary, 1
Supervised Fire/Burglary/Aux, 1
Panic Zone.
- 3 Modes of Programming:
- Keypad Programming
- Locally Downloadable from IBM
Lap Top Computer (or equivalent)
using Napco PCL2000 Local
Downloading Cable and PCI2000
Software.
- Remotely downloadable from IBM
Personal Computer (or equivalent).
- "Sensor Watch", An Exclusive Napco
Feature--Reports Lack of Motion
Detector Activity (per programmed
time duration as a Day Zone Trouble
(non-alarm condition).
- Auto Download Utility (Uses PC
Preset Utility in Standby Mode.)
- Non-Volatile EEPROM Memory
- Exit/Entry Follower Zone(s)
- Chime by Zone-Selectable Duration,
and 7 Segment Display of Chime Zone
- 24-Hour Keypad Annunciation of
Non-Alarm Zone (i.e., driveway alert)
- Swinger Shut-Down by Zone
- Progammable Output (PGM lug) for
various applications
- Remote Keypad Panic Zone
- Programmable E.O.L. Resistor
Disable Feature
- Separate Dealer and User Program Codes
- Flexible Watch Modes
- Auto Bypass, Group Bypass, and
Selectable Bypass
- 2 Separately Programmable Entry
Delay Times; 1 Programmable Exit
Delay Time
- Fire Response is Preprogrammed for
Pulse Output
- 3 Programmable Loop Response Times
- 8 Stages of Lightning/Transient Protection
- Extended Smoke Detector Reset
Interval (reduces the chance of a
second alarm if smoke has not cleared)
- Resumes Previous Status After Power Outages
- Watchdog Circuit
- 24 Hour Automatic Battery Test
|
COMMUNICATOR FEATURES
- Reports In All Major Formats
Including BFSK and 4/2.
- Optional Reporting of Bypass Zones.
- Ability to Dial Touchtone Digit
Labelled ("*" Key) To Disable "Call
Waiting" For the Duration of The Call
(not usable in all areas).
- Opening and Closing Reports By User
- Open Report After Alarm
- Split, Double and Backup Reporting
Capabilities
- Rotary Dialing and Touchtone With
Rotary Backup
- Reports Alarm By Individual Zones
- Conditional Closing Report With Status
- 24-Hour Protection Programmable for
All Zones
- Communicator Confidence Test
- Daily Test Timer (also resetable on any
transmission)
- Alarm and Restore Codes: on fire, fire
trouble, low battery, and AC loss.
SPECIFICATIONS
- Input Power: 16 VAC, Class 2 Step
Down Transformer (TRF-8)
(Supplied)
- Alarm Outputs: Wet Output for Siren,
Bell, etc. 12 VDC, 1A Maximum.
- Combined Standby Current: Remote
Power, Aux. Output, Relay Output
300mA Maximum With Supplied
TRF8, Optional Higher Power TRF12
Transformer Yields 500mA Maximum.
- Standby Time: See Energy Saver
- Loop Resistance: 300 Ohms
- Relay Contact Ratings: 24 VDC, 2A
Resistive
- Remote Station: Maximum Number: 5
- Housing Dimensions: 10-3/8"H
x 8-1/2"W x2-3/4"D
- Shipping Weight: MA100Oe 9 lbs.
MA1000e4 10.5 lbs.
|
KEYPAD FEATURES
- 4-wire hookup
- Sleek, Decorator Design in Classic White
- Fire, Panic and Auxiliary Buttons plus
Ambush Code.
- Audible and Tactile Feedback when
keys are pressed (programmable).
- Up to 8 Arm/Disarm Codes Easily
Changed by User
- Unique Service Code--Which is
Automatically Disabled When User
One Returns and Arms/Disarms the Panel.
- System Troubles Displayed at the
Keypad: AC Fail, Low Battery, Fail-
to-Communicate, Download Error
- Arm Only Code
- Alarm History
- No Display of Bypass Zones While Armed
- Pronounced LED Indication of All
Bypassed Zones
- Programmable Bypass Display
Indicates Auto Bypassed or Priority-
With-Bypass Zones
- Separate Sounder Output
- Fault Find--Facilitates Expedient
Testing and Troubleshooting
- Keypad Offset Time for 24 Hour Test
- "Soft Touch" full-size keys
RP1054e Keypad:
- Digital LED Zone Display
- Concealed, Finger-Tip Zone/Usage
Reference
RP1000eLCD Keypad:
- Large, Backlit LCD Alphanumeric
Zone Directory
- Backlit Keys Brighten When Touched
- Concealed, Finger-Tip Zone/Usage
Reference
|